Performance of optimum tuned PID controller with different feedback strategies on active-controlled structures

dc.authorid0000-0003-0964-0728
dc.contributor.authorUlusoy, Serdar
dc.contributor.authorBekdaş, Gebrail
dc.contributor.authorNiğdeli, Sinan Melih
dc.contributor.authorKim, Sanghun
dc.contributor.authorGeem, Zong Woo
dc.date.accessioned2021-04-26T08:38:31Z
dc.date.available2021-04-26T08:38:31Z
dc.date.issued2021
dc.departmentTAÜ, Mühendislik Fakültesi, İnşaat Mühendisliği Bölümüen_US
dc.description.abstractIn this study, multi-story structures with different combinations (on each floor and only the first floor) of active tendon control systems driven by a proportional-integral-derivative (PID) controller were actively controlled. The PID parameters, K-p (proportional gain), T-d (derivative gain), and T-i (integral gain) for each structure, were optimally tuned by using both the harmony search algorithm (HS) and flower pollination algorithm (FPA), which are metaheuristic algorithms. In two different active-controlled structures, which are formed according to the position of the PID, the structural responses under near-fault records defined in FEMA P-695 are examined to determine the appropriate feedback which was applied for displacement, velocity, acceleration, and total acceleration. The performance of the different feedback strategies on these two active-controlled structures is evaluated. As a result, the acceleration feedback is suitable for all combinations of the active control system with a PID controller. The HS algorithm outperforms the optimum results found according to the FPA.
dc.identifier.citationUlusoy, S., Bekdaş, G., Nigdeli, S. M., Kim, S., & Geem, Z. W. (2021). Performance of Optimum Tuned PID Controller with Different Feedback Strategies on Active-Controlled Structures. Applied Sciences, 11(4), 1682.
dc.identifier.doi10.3390/app11041682
dc.identifier.issn2076-3417
dc.identifier.issue4en_US
dc.identifier.scopus2-s2.0-85101205361
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://hdl.handle.net/20.500.12846/581
dc.identifier.volume11en_US
dc.identifier.wosWOS:000632119500001
dc.identifier.wosqualityQ2
dc.indekslendigikaynakWeb of Science
dc.indekslendigikaynakScopus
dc.institutionauthorUlusoy, Serdar
dc.language.isoen
dc.publisherMDPI-Multidisciplinary Digital Publishing Institute
dc.relation.ispartofApplied Sciences
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectActive Tendon Controlen_US
dc.subjectDerivative Controlen_US
dc.subjectMetaheuristic Algorithmsen_US
dc.subjectFlower Pollination Algorithmen_US
dc.titlePerformance of optimum tuned PID controller with different feedback strategies on active-controlled structures
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
applsci-11-01682-v2.pdf
Boyut:
4.81 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Tam Metin / Full Text
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: