Basit öğe kaydını göster

dc.contributor.authorSchlosser, Dieter Michael
dc.contributor.authorHartmann, Robert
dc.contributor.authorKalok, D.
dc.contributor.authorBechteler, A.
dc.contributor.authorAbboud, Ali
dc.contributor.authorShokr, Mohammad Mahdi
dc.contributor.authorStrüeder, Lothar
dc.contributor.authorÇonka Yıldız, Tuba
dc.date.accessioned2021-01-08T21:51:26Z
dc.date.available2021-01-08T21:51:26Z
dc.date.issued2017
dc.identifier.issn1748-0221
dc.identifier.urihttp://doi.org/10.1088/1748-0221/12/04/P04009
dc.identifier.urihttps://hdl.handle.net/20.500.12846/252
dc.descriptionConka, Tuba/0000-0003-0671-3805en_US
dc.descriptionWOS:000405067800009en_US
dc.description.abstractBy combining a low noise fully depleted pnCCD detector with a columnar CsI(Tl) scintillator an energy dispersive spatial resolving detector can be realized with a high quantum efficiency in the range from below 0.5 keV to above 150 keV. The used scintillator system increases the pulse height of gamma-rays converted in the CsI(Tl), due to focusing properties of the columnar scintillator structure by reducing the event size in indirect detection mode (conversion in the scintillator). In case of direct detection (conversion in the silicon of the pnCCD) the relative energy resolution is 0.7% at 122 keV (FWHM = 850 eV) and the spatial resolution is less than 75 mu m. In case of indirect detection the relative energy resolution, integrated over all event sizes is about 9% at 122 keV with an expected spatial precision of below 75 mu m.en_US
dc.language.isoengen_US
dc.publisherIop Publishing Ltden_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectGamma Detectors (Scintillators, Czt, Hpg, Hgi Etc)en_US
dc.subjectScintillators, Scintillation And Light Emission Processes (Solid, Gas And Liquid Scintillators)en_US
dc.subjectX-Ray Detectorsen_US
dc.subjectDetector Modelling And Simulations I (Interaction Of Radiation With Matter, Interaction Of Photons With Matter, Interaction Of Hadrons With Matter, Etc)en_US
dc.titleA new spectroscopic imager for X-rays from 0.5 keV to 150 keV combining a pnCCD and a columnar CsI(Tl) scintillatoren_US
dc.typearticleen_US
dc.relation.journalJournal Of Instrumentationen_US
dc.identifier.volume12en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.contributor.departmentTAÜ, Mühendislik Fakültesi, Mekatronik Mühendisliği Bölümüen_US
dc.contributor.institutionauthorÇonka Yıldız, Tuba
dc.identifier.doi10.1088/1748-0221/12/04/P04009
dc.identifier.wosqualityQ3en_US
dc.identifier.scopusqualityQ2en_US
dc.identifier.wosWOS:000405067800009en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster