dc.contributor.author | Yarman, Aysu | |
dc.contributor.author | Kurbanoğlu, Sevinç | |
dc.date.accessioned | 2024-12-05T19:21:59Z | |
dc.date.available | 2024-12-05T19:21:59Z | |
dc.date.issued | 2024 | en_US |
dc.identifier.citation | Yarman, A., Kurbanoğlu, S. (2024). A tale of captopril detection based on an electrochemical mip sensör. Ankara Üniversitesi Eczacılık Fakültesi Dergisi, 48 (2), 568-575. | en_US |
dc.identifier.uri | https://search.trdizin.gov.tr/tr/yayin/detay/1236430/a-tale-of-captopril-detection-based-on-an-electrochemical-mip-sensor | |
dc.identifier.uri | https://hdl.handle.net/20.500.12846/1451 | |
dc.description.abstract | Amaç: Bu çalışmada antihipertansif bir ilaç olan Kaptoprilin tespitine yönelik moleküler baskılama yöntemi ile hazırlanmış sensörler kullanılarak voltametrik bir yöntem geliştirilmesi amaçlanmıştır. Gereç ve Yöntem: Moleküler baskılama yöntemi ile camsı karbon elektroların yüzeylerinde moleküler baskınlanmış polimerler oluşturulmuş ve differansiyel puls voltammetri yöntemi ile Kaptoprilin analizi gerçekleştirilmiş, sensörün performansı incelenmiştir. Sonuç ve Tartışma: 2,62 pM teşhis sınırı değeri ile 50 pM Kaptopril seviyesine kadar doğrusal bir analiz gerçekleştirilmiştir. Seçicilik çalışmaları, Kaptoprilin, diğer girişim yapabilecek, parasetamol, askorbik asit ve L-prolin gibi maddelere göre daha yüksek elektrokimyasal cevaba sahip olduğunu göstermiştir. | en_US |
dc.description.abstract | Objective: In this study, it was aimed to develop a voltammetric method using sensors prepared with the molecular imprinting technique for the detection of Captopril, an antihypertensive drug. Material and Method: With the molecular imprinting method, molecularly imprinted polymers were formed on the surfaces of glassy carbon electrodes. The analysis of Captopril was carried out using the differential pulse voltammetry method, and the performance of the sensor was examined. Result and Discussion: A linear analysis was performed up to 50 pM Captopril with a limit of detection value of 2.62 pM. Selectivity studies have shown that Captopril has a higher electrochemical response than other interfering substances, such as paracetamol, ascorbic acid, and L-proline. | en_US |
dc.language.iso | eng | en_US |
dc.relation.isversionof | 10.33483/jfpau.1420660 | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Moleküler baskılanmış polimerler | en_US |
dc.subject | Kaptopril | en_US |
dc.subject | Biyomimetik sensörler | en_US |
dc.subject | Tampon çözelti etkisi | en_US |
dc.subject | Buffer effect | en_US |
dc.subject | Captopril | en_US |
dc.subject | Biomimetic sensors | en_US |
dc.subject | Molecularly imprinted polymers | en_US |
dc.title | A tale of captopril detection based on an electrochemical mip sensör | en_US |
dc.title.alternative | Kartopril tespiti için elektrokimyasal bir mip sensörünün hikayesi | en_US |
dc.type | article | en_US |
dc.relation.journal | Ankara Üniversitesi Eczacılık Fakültesi Dergisi | en_US |
dc.identifier.volume | 48 | en_US |
dc.identifier.issue | 2 | en_US |
dc.relation.publicationcategory | Makale - Ulusal Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.contributor.department | TAÜ, Fen Fakültesi, Moleküler Biyoteknoloji Bölümü | en_US |
dc.identifier.startpage | 568 | en_US |
dc.identifier.endpage | 575 | en_US |