Pull-out strength of screws in long bones at different insertion angles: finite element analysis and experimental investigations

dc.authorid0000-0001-7340-8363
dc.contributor.authorGepek, Engin
dc.contributor.authorİyibilgin, Osman
dc.contributor.authorBayam, Levent
dc.contributor.authorDrampalos, Efstathios
dc.contributor.authorShoaib, Amer
dc.date.accessioned2024-03-28T06:02:09Z
dc.date.available2024-03-28T06:02:09Z
dc.date.issued2024
dc.departmentTAÜ, Mühendislik Fakültesi, Makine Mühendisliği Bölümüen_US
dc.description.abstractDifferent types of plates are available to allow insertion of screws for internal fixation of long bone fractures. The aim of the study was to determine the effect of the insertion of screws at different angles on a long bone to the pull-out strength. Using 3D printed bone models, we tested the pull-out strength of screws in long bones at insertion angles between 0 and 40° with both finite element analysis and on printed models experimentally and compared the results. Test samples and cortical screws used were modeled with SolidWorks software and analyzed with Ansys software. As the screw insertion angle increases, the pull-out forces on the test specimens increase from 61.14 ± 3.5 N at 0° to 273 ± 6.8 N at 40° with an exception of a small drop between 15 and 20° from 235.4 ± 6.2 to 233 ± 6.9 N. Both methods showed an increase in the pull-out strength of screws as the insertion angle increases. This might be applicable in the clinical practice of bone fixation. Further studies on plate and screw fixation are needed to complement the findings.
dc.identifier.citationGepek, E., İyibilgin, O., Bayam, L., Drampalos, E. ve Shoaib, A. (2024). Pull-out strength of screws in long bones at different insertion angles: finite element analysis and experimental investigations. De Gruyter içerisinde 66 (3), 380-388. De Gruyter.
dc.identifier.doi10.1515/mt-2023-0239
dc.identifier.endpage388en_US
dc.identifier.issue3en_US
dc.identifier.scopus2-s2.0-85183851725
dc.identifier.startpage380en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12846/943
dc.identifier.volume66en_US
dc.identifier.wosWOS:001148116300001
dc.indekslendigikaynakWeb of Science
dc.language.isoen
dc.publisherDe Gruyter
dc.relation.ispartofMechanical Testing
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectPull-out strengthen_US
dc.subjectFibula fixationen_US
dc.subjectFinite element analysisen_US
dc.subjectAdditive manufacturingen_US
dc.subjectExperimental studyen_US
dc.titlePull-out strength of screws in long bones at different insertion angles: finite element analysis and experimental investigations
dc.typeArticle

Dosyalar

Orijinal paket
Listeleniyor 1 - 1 / 1
Yükleniyor...
Küçük Resim
İsim:
10.1515_mt-2023-0239_2024 material testing1.pdf
Boyut:
2.39 MB
Biçim:
Adobe Portable Document Format
Açıklama:
Makale Dosyası
Lisans paketi
Listeleniyor 1 - 1 / 1
[ X ]
İsim:
license.txt
Boyut:
1.44 KB
Biçim:
Item-specific license agreed upon to submission
Açıklama: