Basit öğe kaydını göster

dc.contributor.authorGepek, Engin
dc.contributor.authorİyibilgin, Osman
dc.contributor.authorBayam, Levent
dc.contributor.authorDrampalos, Efstathios
dc.contributor.authorShoaib, Amer
dc.date.accessioned2024-03-28T06:02:09Z
dc.date.available2024-03-28T06:02:09Z
dc.date.issued2024en_US
dc.identifier.citationGepek, E., İyibilgin, O., Bayam, L., Drampalos, E. ve Shoaib, A. (2024). Pull-out strength of screws in long bones at different insertion angles: finite element analysis and experimental investigations. De Gruyter içerisinde 66 (3), 380-388. De Gruyter.en_US
dc.identifier.urihttps://hdl.handle.net/20.500.12846/943
dc.description.abstractDifferent types of plates are available to allow insertion of screws for internal fixation of long bone fractures. The aim of the study was to determine the effect of the insertion of screws at different angles on a long bone to the pull-out strength. Using 3D printed bone models, we tested the pull-out strength of screws in long bones at insertion angles between 0 and 40° with both finite element analysis and on printed models experimentally and compared the results. Test samples and cortical screws used were modeled with SolidWorks software and analyzed with Ansys software. As the screw insertion angle increases, the pull-out forces on the test specimens increase from 61.14 ± 3.5 N at 0° to 273 ± 6.8 N at 40° with an exception of a small drop between 15 and 20° from 235.4 ± 6.2 to 233 ± 6.9 N. Both methods showed an increase in the pull-out strength of screws as the insertion angle increases. This might be applicable in the clinical practice of bone fixation. Further studies on plate and screw fixation are needed to complement the findings.en_US
dc.language.isoengen_US
dc.publisherDe Gruyteren_US
dc.relation.isversionof10.1515/mt-2023-0239en_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectPull-out strengthen_US
dc.subjectFibula fixationen_US
dc.subjectFinite element analysisen_US
dc.subjectAdditive manufacturingen_US
dc.subjectExperimental studyen_US
dc.titlePull-out strength of screws in long bones at different insertion angles: finite element analysis and experimental investigationsen_US
dc.typearticleen_US
dc.relation.journalMechanical Testingen_US
dc.contributor.authorID0000-0001-7340-8363en_US
dc.identifier.volume66en_US
dc.identifier.issue3en_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.contributor.departmentTAÜ, Mühendislik Fakültesi, Makine Mühendisliği Bölümüen_US
dc.identifier.startpage380en_US
dc.identifier.endpage388en_US


Bu öğenin dosyaları:

Thumbnail

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster