dc.contributor.author | Zolfaghari, Parviz | |
dc.contributor.author | Erden, Oğuz K. | |
dc.contributor.author | Tümer, Murat | |
dc.contributor.author | Yalçınkaya, Arda D. | |
dc.contributor.author | Ferhanoğlu, Onur | |
dc.date.accessioned | 2023-03-08T12:46:56Z | |
dc.date.available | 2023-03-08T12:46:56Z | |
dc.date.issued | 2023 | en_US |
dc.identifier.citation | We present a stacked temperature, pressure, and localization platform, targeted for minimally invasive surgical and diagnostic applications under Magnetic Resonance Imaging. The platform comprises a micro-fabricated three-layer (Titanium-Parylene-Titanium) membrane pressure sensor, a Gallium Arsenide band-gap temperature sensor, and a magnetic material on double prism retro-reflector that benefits from Magneto-Optic Kerr effect as a magnetic field sensor, to provide localization feedback under Magnetic Resonance Imaging. All sensors can be addressed with a single fiber optic cable, where the collected light is directed to a spectrometer and a polarimeter. For the three-layer microfabricated membrane sensor, an analytical formulation is derived, linking the pressure to optical intensity. Moreover, finite-element simulation results are provided, verifying analytical findings. Wavelength division multiplexing is exploited to address the sensors simultaneously. We measured sensitivities of 0.025 millidegree/Gauss rotation of polarization, 1.5 nm/mmHg displacement (in agreement with simulation results and analytical findings), 0.36 nm/degrees C. bandgap wavelength shift for magnetic field, pressure, and temperature sensors; respectively. With further development, the proposed device can be adapted to a clinical setting for use in Magnetic Resonance assisted surgical procedures. | en_US |
dc.identifier.uri | https://hdl.handle.net/20.500.12846/707 | |
dc.description.abstract | We present a stacked temperature, pressure, and localization platform, targeted for minimally invasive surgical and diagnostic applications under Magnetic Resonance Imaging. The platform comprises a micro-fabricated three-layer (Titanium-Parylene-Titanium) membrane pressure sensor, a Gallium Arsenide band-gap temperature sensor, and a magnetic material on double prism retro-reflector that benefits from Magneto-Optic Kerr effect as a magnetic field sensor, to provide localization feedback under Magnetic Resonance Imaging. All sensors can be addressed with a single fiber optic cable, where the collected light is directed to a spectrometer and a polarimeter. For the three-layer microfabricated membrane sensor, an analytical formulation is derived, linking the pressure to optical intensity. Moreover, finite-element simulation results are provided, verifying analytical findings. Wavelength division multiplexing is exploited to address the sensors simultaneously. We measured sensitivities of 0.025 millidegree/Gauss rotation of polarization, 1.5 nm/mmHg displacement (in agreement with simulation results and analytical findings), 0.36 nm/degrees C. bandgap wavelength shift for magnetic field, pressure, and temperature sensors; respectively. With further development, the proposed device can be adapted to a clinical setting for use in Magnetic Resonance assisted surgical procedures. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Elsevier | en_US |
dc.relation.isversionof | 10.1016/j.optlaseng.2022.107323 | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Sensors | en_US |
dc.subject | MEMS | en_US |
dc.subject | Fiber Optics | en_US |
dc.subject | Magnetic Resonance Imaging | en_US |
dc.subject | Wavelength Division Multiplexing | en_US |
dc.subject | Sensörler | en_US |
dc.subject | Fiber Optik | en_US |
dc.subject | Manyetik Rezonans Görüntüleme | en_US |
dc.subject | Dalgaboyu Bölmeli Çoğullama | en_US |
dc.subject | Sensoren | en_US |
dc.subject | Faseroptik | en_US |
dc.subject | Magnetresonanz Bildgebung | en_US |
dc.subject | Wellenlängen Multiplexing | en_US |
dc.title | A stacked multi-sensor platform for real-time MRI guided interventions | en_US |
dc.type | article | en_US |
dc.relation.journal | Optics and Lasers in Engineering | en_US |
dc.contributor.authorID | 0000-0003-0989-8761 | en_US |
dc.identifier.volume | 161 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.contributor.department | TAÜ, Mühendislik Fakültesi, Elektrik-Elektronik Mühendisliği Bölümü | en_US |
dc.contributor.institutionauthor | Tümer, Murat | |
dc.identifier.wosquality | Q1 | en_US |
dc.identifier.wos | WOS:000882512000007 | en_US |