dc.contributor.author | İncekar, Erkan | |
dc.contributor.author | Kaygısz, Hüseyin | |
dc.contributor.author | Babur, Sebahattin | |
dc.date.accessioned | 2021-12-24T08:39:06Z | |
dc.date.available | 2021-12-24T08:39:06Z | |
dc.date.issued | 2021 | en_US |
dc.identifier.citation | İncekar E., Kaygısız H. ve Babur S., “Dimensional accuracy analysis of samples printed in delta and cartesian kinematic three dimensional printers”, Politeknik Dergisi, 24(2): 529-537, (2021). | en_US |
dc.identifier.issn | 1302-0900 | |
dc.identifier.issn | 2147-9429 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12846/610 | |
dc.description.abstract | The motion mechanisms of manufacturing and robotic systems are developed in different structures, mainly in cartesian and delta structures having series or parallel movement abilities according to the capacity and construction structure of the system. Different systems are used according to the criteria such as bearing load capacity, sensitivity or cost of the system. In this study, the performances of machines installed in the delta and cartesian kinematic structures, which are mostly used in the kinematic systems of three - dimensional printers, were analyzed. In this context, in two different machines with these two construction structures, the same boundary conditions and 4 pieces of calibration parts especially in manufacturing features were printed. 23 different elements that constituted the calibration part were measured, tabulated, statistically analyzed, and the acceptable measuremental tolerance ranges of the elements were determined and the accuracy values of the machines were compared. As a result of this study, according to T test results, 15 of the 23 measurements on the Cartesian system based three-dimensional printers were obtained as acceptable in terms of tolerance range as well as 9 of the 23 different measurements were obtained as acceptable on Delta system. Consequently, operation accuracy of the Cartesian system based three-dimensional printers were higher than the Delta system under the same working conditions and manufacturing parameters. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Gazi Üniversitesi | en_US |
dc.relation.isversionof | 10.2339/politeknik.582410 | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Accuracy Measurement | en_US |
dc.subject | Delta Printer | en_US |
dc.subject | Cartesian Printer | en_US |
dc.subject | Genauigkeitsmessung | en_US |
dc.subject | Kartesischer Drucker | en_US |
dc.subject | Delta Drucker | en_US |
dc.subject | Doğruluk Ölçümü | en_US |
dc.subject | Delta Yazıcı | en_US |
dc.subject | Kartezyen Yazıcı | en_US |
dc.title | Dimensional accuracy analysis of samples printed in delta and cartesian kinematic three dimensional printers | en_US |
dc.title.alternative | Delta ve kartezyen kinematik yapılı üç boyutlu yazıcılarda basılan numunelerin boyutsal doğruluk analizi | en_US |
dc.type | article | en_US |
dc.relation.journal | Politeknik Dergisi | en_US |
dc.contributor.authorID | 0000-0002-2982-8405 | en_US |
dc.identifier.volume | 24 | en_US |
dc.identifier.issue | 2 | en_US |
dc.relation.publicationcategory | Konferans Öğesi - Uluslararası - Kurum Öğretim Elemanı | en_US |
dc.contributor.department | TAÜ | en_US |
dc.contributor.institutionauthor | Babur, Sebahattin | |
dc.identifier.startpage | 529 | en_US |
dc.identifier.endpage | 537 | en_US |
dc.identifier.wosquality | N/A | en_US |