Basit öğe kaydını göster

dc.contributor.authorŞimşek, Görkem Muttalip
dc.contributor.authorİpekoğlu, Mehmet
dc.contributor.authorYapıcı, Güney Güven
dc.date.accessioned2021-01-08T21:51:31Z
dc.date.available2021-01-08T21:51:31Z
dc.date.issued2020
dc.identifier.isbn9783035737059
dc.identifier.issn0255-5476
dc.identifier.urihttps://doi.org/10.4028/www.scientific.net/MSF.1015.108
dc.identifier.urihttps://hdl.handle.net/20.500.12846/329
dc.description8th Asia Conference on Mechanical and Materials Engineering, ACMME 2020, 11 June 2020 through 14 June 2020, , 252569en_US
dc.description.abstractMetallic materials including stainless steel, cobalt-chromium alloys, titanium and its alloys, and nickel-titanium (NiTi) shape memory alloys have been used in biomedical applications since the 1940s due to their favorable mechanical properties. Classified as a smart material, NiTi alloy has gained noticeable popularity in biomedical fields such as orthopedic, dental, and cardiovascular applications as it retains reasonable corrosion resistance and biocompatibility along with unique shape memory properties. However, several studies have shown their limits in medical applications due to the risk of Ni ions release from the NiTi implant surface. In order to prevent Ni release, ceramic-based surface coatings such as hydroxyapatite, alumina, and titanium dioxide have been proposed applied by various methods such as electrophoretic deposition, sol-gel, biomimetic and dip coating. In this work, HA coatings on NiTi wire samples were obtained by using biomimetic and dip-coating methods. The biomimetic coating consisted of immersing the NiTi wire samples into simulated body fluid for 24 and 48 h periods, whereas dip coating was accomplished by placing the NiTi wire samples into the HA suspension and retracting the sample with a controlled speed. The effects of the two coating methods on coating quality, surface characteristics and corrosion behavior of NiTi wire samples were investigated. Dip coating method was shown to be a more favorable technique for the NiTi wire samples used throughout this study. © 2020 Trans Tech Publications Ltd, Switzerland.en_US
dc.language.isoengen_US
dc.publisherTrans Tech Publications Ltden_US
dc.rightsinfo:eu-repo/semantics/closedAccessen_US
dc.subjectBiomimetic coatingen_US
dc.subjectCorrosionen_US
dc.subjectDip-coatingen_US
dc.subjectHydroxyapatiteen_US
dc.subjectNickel-titaniumen_US
dc.titleEffect of coating method on the surface characteristics of niti shape memory alloyen_US
dc.typeconferenceObjecten_US
dc.relation.journalMaterials Science Forumen_US
dc.identifier.volume1015 MSFen_US
dc.relation.publicationcategoryKonferans Öğesi - Uluslararası - Kurum Öğretim Elemanıen_US
dc.contributor.departmentTAÜ, Mühendislik Fakültesi, Makine Mühendisliği Bölümüen_US
dc.contributor.institutionauthorİpekoğlu, Mehmet
dc.identifier.doi10.4028/www.scientific.net/MSF.1015.108
dc.identifier.startpage108en_US
dc.identifier.endpage112en_US
dc.identifier.scopusqualityQ4en_US


Bu öğenin dosyaları:

DosyalarBoyutBiçimGöster

Bu öğe ile ilişkili dosya yok.

Bu öğe aşağıdaki koleksiyon(lar)da görünmektedir.

Basit öğe kaydını göster