dc.contributor.author | Uğur, Mukden | |
dc.contributor.author | Atalar, Fatih | |
dc.contributor.author | Önhon, N.Özben | |
dc.date.accessioned | 2024-04-04T13:50:45Z | |
dc.date.available | 2024-04-04T13:50:45Z | |
dc.date.issued | 2023 | en_US |
dc.identifier.citation | Uğur, M., Atalar, F., Önhon, N.Ö. (2023). Investigation of the effect of layered structure on partial discharges in transformer pressboard insulator. Electrical Engineering içerisinde 105, 3459-3467. | en_US |
dc.identifier.uri | https://hdl.handle.net/20.500.12846/1003 | |
dc.description.abstract | The dielectric performance of pressboards impregnated with mineral oil is one of the key points in regard to the quality
of the transformer’s working life. Partial discharges (PDs) occurring in the pressboard can cause some insulation defects
which might be one of the major reasons for an electrical breakdown. Detection of the PDs in pressboards gives a chance to
understand the dielectric behavior of the insulators, hence major defects can be prevented just in early stage. The main point
of the study is to investigate the differences in dielectric performance of layered and non-layered pressboards in the presence
of PDs. For this purpose, the PD behavior of a layered pressboard with three layers (each with a thickness of 0.5 mm) and
of a non-layered (solid) pressboard (with a thickness of 1.5 mm) is examined for two different high voltage levels (20 and
30 kV). To detect the PDs, Hall Effect Sensors are employed, considering that PDs cause fluctuations in the magnetic field. To
analyze the magnetic field measurements from a statistical point of view, the Kaplan–Meier method and the Weibull analysis
are used. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Springer | en_US |
dc.relation.isversionof | 10.1007/s00202-023-01903-6 | en_US |
dc.rights | info:eu-repo/semantics/openAccess | en_US |
dc.subject | Layered pressboards | en_US |
dc.subject | Non-layered pressboards | en_US |
dc.subject | Partial discharge | en_US |
dc.subject | Kaplan–Meier method | en_US |
dc.subject | Weibull analysis | en_US |
dc.title | Investigation of the effect of layered structure on partial discharges in transformer pressboard insulator | en_US |
dc.type | article | en_US |
dc.relation.journal | Electrical Engineering | en_US |
dc.contributor.authorID | 0000-0002-3399-9346 | en_US |
dc.identifier.issue | 105 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.contributor.department | TAÜ, Fen Bilimleri Enstitüsü, Robotlar ve Akıllı Sistemler Ana Bilim Dalı Koleksiyonu | en_US |
dc.identifier.startpage | 3459 | en_US |
dc.identifier.endpage | 3467 | en_US |