    Determination of heat transfer coefficient between heated floor and space using the principles of ANSI/ASHRAE Standard 138 test chamber
    (Amer Soc Heating, Refrigerating And Air-Conditioning Engs, 2017) Evren, Fatih; Özsunar, Abuzer; Bıyıkoğlu, Atilla; Kılkış, Birol
    In this study, heat transfer coefficients for radiant floor heating systems were investigated in a special test chamber that is one of the very first implementations of ANSI/ASHRAE Standard 138 in the world. Radiant systems offer high energy- and exergy-efficient sensible heating and cooling potential. These systems can be directly coupled with low enthalpy, renewable, or waste heat resources. Heat transfer coefficients are important design parameters for radiant systems that effect the heat transfer capacity of the heated/cooled surface to the indoors. In this study, radiant, convective, and total heat transfer coefficients for radiant floor heating were investigated experimentally. Experiments were conducted in a special test chamber that was established according to ANSI/ASHRAE Standard 138 with minor differences. The test chamber dimensions are 2.74 x 2.25 x 2.45 m (8.99 x 7.38 x 8.04 ft) and there are no floor coverings during the test. Coefficients were determined through two difference methods. Heat fluxes from the heated floor that calculated via both methods and obtained from the "Design Graph for Sensible Heating and Cooling with Floor and Ceiling" in ASHRAE Handbook-HVAC Systems and Equipment (ASHRAE 2008). According to the experimental results, total heat transfer coefficients for the radiant heating system were obtained between 8.8 and 12.1 W/m(2)K (1.43 and 2.13 Btu/h.ft(2).degrees F).

| Türk-Alman Üniversitesi | Kütüphane | Rehber | OAI-PMH |

Bu site Creative Commons Alıntı-Gayri Ticari-Türetilemez 4.0 Uluslararası Lisansı ile korunmaktadır.


Türk-Alman Üniversitesi, Beykoz, İstanbul, TÜRKİYE
İçerikte herhangi bir hata görürseniz lütfen bize bildirin

DSpace 7.6.1, Powered by İdeal DSpace

DSpace yazılımı telif hakkı © 2002-2026 LYRASIS

  • Çerez Ayarları
  • Gizlilik Politikası
  • Son Kullanıcı Sözleşmesi
  • Geri Bildirim