Ara
Toplam kayıt 7, listelenen: 1-7
Single-shot full strain tensor determination with microbeam X-ray Laue diffraction and a two-imensional energy-dispersive detector
(Int Union Crystallography, 2017)
The full strain and stress tensor determination in a triaxially stressed single crystal using X-ray diffraction requires a series of lattice spacing measurements at different crystal orientations. This can be achieved using ...
A new spectroscopic imager for X-rays from 0.5 keV to 150 keV combining a pnCCD and a columnar CsI(Tl) scintillator
(Iop Publishing Ltd, 2017)
By combining a low noise fully depleted pnCCD detector with a columnar CsI(Tl) scintillator an energy dispersive spatial resolving detector can be realized with a high quantum efficiency in the range from below 0.5 keV to ...
GamSim - a windows-based simulation tool for Gamma-Ray detector development
(Ieee, 2016)
After the introduction of radiation simulation tools such as Geant4 or EGS in nuclear and high energy physics, the use in applied fields like nuclear medicine becomes increasingly important and a number of extensions have ...
Direct and indirect signal detection of 122 keV photons with a novel detector combining a pnCCD and a CsI(T1) scintillator
(Elsevier, 2016)
By combining a low noise fully depleted pnCCD detector with a CsI(TI) scintillator, an energy-dispersive area detector can be realized with a high quantum efficiency (QE) in the range from below 1 keV to above 100 keV. In ...
Application of a pnCCD for energy-dispersive Lauc diffraction with ultra-hard X-rays
(Int Union Crystallography, 2015)
In this work the spectroscopic performance of a pnCCD detector in the ultra-hard energy range between 40 and 140 keV is tested by means of an energy-dispersive Laue diffraction experiment on a GaAs crystal. About 100 Bragg ...
Applications of a pnCCD detector coupled to columnar structure CsI(Tl) scintillator system in ultra high energy X-ray Laue diffraction
(Iop Publishing Ltd, 2017)
Most charge coupled devices (CCDs) are made of silicon (Si) with typical active layer thicknesses of several microns. In case of a pnCCD detector the sensitive Si thickness is 450 mu m. However, for silicon based detectors ...
Design criteria for a high energy Compton Camera and possible application to targeted cancer therapy
(Iop Publishing Ltd, 2015)
The proposed research focuses on the design criteria for a Compton Camera with high spatial resolution and sensitivity, operating at high gamma energies and its possible application for molecular imaging. This application ...